    <description>A strong PLC portfolio</description>
    <language>en</language>
    <lastBuildDate>Thu, 18 Jun 2026 06:06:19 GMT</lastBuildDate>

        <category domain="product-status">Active</category>
        <deif:key>57a97b6e-8085-49de-bd10-eddc24178ea8</deif:key>
        <deif:tagline><![CDATA[A strong PLC portfolio]]></deif:tagline>
        <deif:teaser><![CDATA[]]></deif:teaser>
        <deif:description><![CDATA[<p>The Series 600 modules expand the capabilities of the <a href="/products/ie-650-plc/" title="iE 650 PLC">iE650 PLC</a>, giving you extensive options for communication, I/O, power supply, measurement, and temperature sensing. With a wide portfolio including digital, analogue, relay, communication, and computing modules, the Series 600 range allows you to configure your iE650 PLC solution precisely to your application requirements – whether you need to integrate multiple fieldbus protocols, add high-frequency measurement capabilities, or scale your system with additional I/O.</p>
<p><strong>Flexible, scalable architecture</strong></p>
<p>The modular Series 600 platform lets you build an architecture that matches your exact needs. Simply select and install the required modules into the <a href="/products/ie-650-plc/" title="iE 650 PLC">iE650 PLC</a>’s modular rack. Because each module is field-replaceable, you can quickly adapt your installation as your system or application evolves.</p>
<p><strong>Built for reliability in demanding environments</strong></p>
<p>Series 600 modules are designed for dependable operation, even in harsh or mission-critical environments. All components undergo extensive testing to ensure they deliver stable performance under extreme conditions. The modules are CE marked and UL certified, and they comply with the standards of major classification societies, ensuring suitability for marine and industrial applications.</p>
<p>Click Modules for a complete overview and detailed descriptions of each Series 600 module.</p>]]></deif:description>
        <deif:modules>
            <deif:module>
              <deif:id>24583</deif:id>
              <deif:guid>e865bb44-ec0b-4fa6-b169-821a82eaa28d</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/communication/ifm61/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The IFM6‧1 is designed for the rough environment in a wind turbine, and all inputs and outputs are protected and isolated from other potentials.</p>
<p>The module offers 2 x Profibus DP master and 2 x RS-485 ports.</p>]]></deif:description>
              <deif:features><![CDATA[<p>2 x Profibus DP Master</p>
<ul>
<li>Data rate: 9600, 19200, 45450, 93750, 187500, 500000, 1.5M, 3.0M, 6.0M, 12.0M baud</li>
<li>On-board termination (software-selectable)</li>
</ul>
<p>&nbsp;</p>
<p>2 x RS-485 interfaces</p>
<ul>
<li>Data rate: 2400, 4800, 9600, 19200, 38400, 45450, 57600, 115200, 230400, 460800 baud</li>
<li>On-board termination (software-selectable)</li>
</ul>
<p>&nbsp;</p>
<p>Isolation: Every communication port is isolated from other potentials, 500 V DC</p>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24584</deif:id>
              <deif:guid>7e06eac1-dbe6-4756-9eaf-c1a5227917b3</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/communication/ifm62/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The IFM6‧2 is designed for the rough environment in a wind turbine, and communication ports are protected and isolated from other potentials. The IFM6‧2 interface and Fieldbus module offers 2 x CAN, 2 x SSI and 2 x High-speed counter input.</p>]]></deif:description>
              <deif:features><![CDATA[<p>2 x CAN interfaces</p>
<ul>
<li>Data rate: 20, 50, 100, 125, 250, 500, 800 or 1000 kbps</li>
<li>Isolation: Isolated from other potentials, 500 V DC</li>
</ul>
<p>&nbsp;</p>
<p>2 x SSI</p>
<ul>
<li>Data rate: 250 kbps and 1000 kbps</li>
<li>Isolation: See datasheet.</li>
</ul>
<p>&nbsp;</p>
<p>2 x Digital input with frequency measurement <br>High: 13 to 30 V <br>Low: -30 V to +5 V</p>
<ul>
<li>Bandwith: 125 kHz hardware low-pass filter</li>
</ul>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24586</deif:id>
              <deif:guid>4490ffe8-8665-44f4-9ef3-b1603f757a36</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/computing/pcm6-2/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The PCM6‧2 module comes with a powerful 1.6 GHz quad-core (64 bit) CPU, well suited for demanding C/C++ and CODESYS applications. Use the network functions for energy and power applications, for example, wind turbines, power parks, hybrid solutions, and battery storage.</p>]]></deif:description>
              <deif:features><![CDATA[<p>Processor: 1.6 GHz quad-core industrial grade ARMv8 64 bit CPU with ECC protected cache</p>
<p>Memory: 4 GB LPDDR4 with inline Error Code Correction (ECC)</p>
<p>Digital I/O: 1 input + 1 output</p>
<p>Ethernet: 1 x 100/1000BASE-T + 3 X 10/100BASE-T (managed switch)</p>
<p>2 x CAN</p>
<p>2 x RS-422/485</p>
<p>Display port v1.3 1080p</p>
<p>USB 3.0 host</p>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24062</deif:id>
              <deif:guid>4dc8428d-4335-4587-9d24-40f36d074f83</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/computing/pcm33/</deif:link>
              <deif:teaser><![CDATA[<p>Housed in the primary controller rack, the processor and communication module contains the controller's main microprocessor, which runs the controller application software.</p>]]></deif:teaser>
              <deif:description><![CDATA[<p>Housed in the primary controller rack, the processor and communication module contains the controller's main microprocessor, which runs the controller application software. It includes the Ethernet switch to manage the controller Ethernet connections, with four 100BASE-TX Ethernet connections. It has a Self-check OK LED. It also contain 4 sets of CAN bus terminals, 2 sets RS422/RS-485 terminals and USB storage port. The PCM3.3 performs time synchronization with and NTP server.</p>]]></deif:description>
              <deif:features><![CDATA[<h4>Physical connections</h4>
<ul>
<li>4 x 100BASE-TX Ethernet
<ul>
<li>DEIF network</li>
<li>SCADA</li>
<li>Alarm Monitoring System</li>
<li>Modbus TCP/IP</li>
</ul>
</li>
<ul>
<li>Service PC</li>
<li>Display unit</li>
<li>Configurable</li>
</ul>
<li>4 x CAN bus</li>
<li>2 x RS-422/RS 485</li>
</ul>
<h4>Controller temperature too high</h4>
<ul>
<li>This is a built-in alarm for the controller internal temperature, as measured on PCM3.3</li>
</ul>
<h4>PCM3.3 clock battery</h4>
<ul>
<li>PCM3.3 includes an internal battery for timekeeping during a power supply failure. If there is no power supplied to the controller or the PCM module, the controller uses the battery power for its internal clock.</li>
</ul>
<ul>
<li>The PCM clock battery failure alarm is activated when the battery in PCM3.3 needs to be replaced</li>
</ul>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24581</deif:id>
              <deif:guid>ce949ad8-22b3-427a-8b9b-eaad261e2a79</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/analogue-io/aim6-1/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The AIM6‧1 has 16 analogue inputs with individually configurable voltage and current modes. All the inputs are protected and isolated from other potentials.</p>]]></deif:description>
              <deif:features><![CDATA[<p>16 x Analogue inputs</p>
<p>Input type:</p>
<ul>
<li>Current mode: 0 to 20 mA, 4 to 20 mA, -20 to 20 mA</li>
<li>Voltage mode: 0 to 10 V, -10 to 10 V</li>
<li>Software selectable.</li>
</ul>
<p>Isolation: 4 isolation groups (4+4+4+4).</p>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24582</deif:id>
              <deif:guid>f19530cf-5582-445b-98c8-779483cb8b26</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/analogue-io/aim6-2/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The AIM6‧2 has 8 analogue inputs with individually configurable voltage and current modes. All the inputs are protected and isolated from other potentials.</p>]]></deif:description>
              <deif:features><![CDATA[<p>8 x Analogue inputs</p>
<p>Input type:</p>
<ul>
<li>Current mode: 0 to 20 mA, 4 to 20 mA, -20 to 20 mA</li>
<li>Voltage mode: 0 to 10 V, -10 to 10 V</li>
<li>Software selectable.</li>
</ul>
<p>Isolation: 2 isolation groups (4+4).</p>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24644</deif:id>
              <deif:guid>5e0a8482-f649-4217-aab1-74d0328611e9</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/analogue-io/aio61/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The AIO6‧1 is designed for the rough environment in a wind turbine, and all inputs and outputs are protected and isolated from other potentials.</p>]]></deif:description>
              <deif:features><![CDATA[<p>16 x Analogue inputs</p>
<p>Input type:</p>
<ul>
<li>Current mode: 0 to 20 mA, 4 to 20 mA, -20 to 20 mA</li>
<li>Voltage mode: 0 to 10 V, -10 to 10 V</li>
<li>Software selectable.</li>
</ul>
<p>Isolation: 2 isolation groups (8+8).</p>
<p>&nbsp;</p>
<p>2 x Analogue outputs</p>
<p>Output type:</p>
<ul>
<li>Current mode : 0 to 20 mA, 4 to 20 mA</li>
<li>Voltage mode : 0 to 10 V, -10 to 10 V.</li>
<li>Software selectable.</li>
</ul>
<p>Isolation: 1 isolation group.</p>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24645</deif:id>
              <deif:guid>267900b8-d35e-448c-aae6-6a0eb8694c33</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/analogue-io/aio62/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The AIO6‧2 has 8 analogue inputs and 8 analogue outputs. The voltage and current modes for the inputs and outputs are individually software configurable. All the inputs and outputs are protected and isolated from other potentials.</p>]]></deif:description>
              <deif:features><![CDATA[<p>8 x Analogue inputs</p>
<p>Input type:</p>
<ul>
<li>Current mode: 0 to 20 mA, 4 to 20 mA, -20 to 20 mA</li>
<li>Voltage mode: 0 to 10 V, -10 to 10 V</li>
<li>Software selectable.</li>
</ul>
<p>Isolation: 2 isolation groups (4+4)</p>
<p>&nbsp;</p>
<p>8 x Analogue outputs</p>
<p>Output type:</p>
<ul>
<li>Current mode : 0 to 20 mA, 4 to 20 mA, -20 to 20 mA.</li>
<li>Voltage mode : 0 to 10 V, -10 to 10 V.</li>
<li>Software selectable.</li>
</ul>
<p>Isolation: 2 isolation groups (4+4)</p>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24646</deif:id>
              <deif:guid>bc1c6847-e302-465e-9aac-5e3fcf9dd18c</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/analogue-io/aom62/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The AOM6‧2 has 8 analogue outputs. The voltage and current modes for the outputs are individually software configurable. The outputs are protected and isolated from other potentials.</p>]]></deif:description>
              <deif:features><![CDATA[<p>8 x Analogue outputs</p>
<p>Output type:</p>
<ul>
<li>Current mode : 0 to 20 mA, 4 to 20 mA, -20 to 20 mA.</li>
<li>Voltage mode : 0 to 10 V, -10 to 10 V.</li>
<li>Software selectable.</li>
</ul>
<p>Isolation: 2 isolation groups (4+4).</p>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24649</deif:id>
              <deif:guid>60dab308-1485-48bf-862f-9be888c4a176</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/digital-io/dio61/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The DIO6‧1 is designed for the rough environment in a wind turbine, and all inputs and outputs are protected and isolated from other potentials.</p>]]></deif:description>
              <deif:features><![CDATA[<p>16 x Digital inputs<br>High: 13 to 30 V<br>Low: -30 V to +5 V<br>Reference to common<br>Isolation: 2 isolation groups (8+8).</p>
<p>10 x Digital outputs<br>External supply: 12 to 32 V<br>Isolation: 1 isolation group</p>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24650</deif:id>
              <deif:guid>eca52ecf-1377-4820-b330-b6632ae24921</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/digital-io/dio62/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The DIO6‧2 has 16 x digital inputs and 16 x digital outputs. All the inputs and outputs are protected and isolated from other potentials.</p>]]></deif:description>
              <deif:features><![CDATA[<p>16 x Digital inputs<br>High: 13 to 30 V<br>Low: -30 V to +5 V<br>Reference to common<br>Isolation: 2 isolation groups (8+8).</p>
<p>16 x Digital outputs<br>External supply: 12 to 32 V<br>Isolation: 2 isolation groups (8+8).</p>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24589</deif:id>
              <deif:guid>83bd663b-a584-4ab7-b1b1-950eb45c7a13</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/digital-io/dim6-1/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The DIM6‧1 has 32 x digital inputs. All the inputs are protected and isolated from other potentials</p>]]></deif:description>
              <deif:features><![CDATA[<p>32 x Digital inputs<br>High: 13 to 30 V<br>Low: -30 V to +5 V<br>Reference to common<br>Isolation: 4 isolation group (8+8+8+8).</p>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24651</deif:id>
              <deif:guid>970936f1-9795-4107-8088-29067c7352a4</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/digital-io/dom61/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The DOM6‧1 has 32 x digital outputs. All the outputs are protected and isolated from other potentials</p>]]></deif:description>
              <deif:features><![CDATA[<p>32 x Digital outputs<br>External supply: 12 to 32 V<br>Isolation: 4 isolation groups (8+8+8+8).</p>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24652</deif:id>
              <deif:guid>a1e823bd-850a-4345-aa40-6c5a9f013301</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/relay-output/rom61/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The ROM6‧1 has 8 normally open relays.</p>]]></deif:description>
              <deif:features><![CDATA[<p>8 x NO (normally open) relay outputs</p>
<ul>
<li>See datasheet for ratings and isolation information</li>
</ul>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24653</deif:id>
              <deif:guid>86137e15-8f95-4ab0-9a92-0b2a5c1bce82</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/relay-output/rom62/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The ROM6‧1 has 4 changeover relays.</p>]]></deif:description>
              <deif:features><![CDATA[<p>4 x changeover relay outputs</p>
<ul>
<li>See datasheet for ratings and isolation information</li>
</ul>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24655</deif:id>
              <deif:guid>ed7328f9-aae9-48fb-b47d-9634d48c09ce</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/station-interface/sim61/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The SIM6‧1 has 2 optical EtherCAT connections (IN/OUT).</p>]]></deif:description>
              <deif:features><![CDATA[<p>1 x EtherCAT IN (Port 0)<br>Optical: 100BASE-FX, SC connectors, multimode fibre glass 50 µm (OM2,OM3,OM4, 1310 nm)<br>1 x EtherCAT OUT (Port 1)<br>Optical: 100BASE-FX, SC connectors, multimode fibre glass 50 µm (OM2,OM3,OM4, 1310 nm)</p>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24656</deif:id>
              <deif:guid>2ed7f5a3-7a78-4fe7-9422-dc42d03d55a7</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/station-interface/sim62/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The SIM6‧2 has an optical and RJ45 EtherCAT OUT connection.</p>]]></deif:description>
              <deif:features><![CDATA[<p>1 x EtherCAT OUT (Port 1)<br>Optical: 100BASE-FX, SC connectors, multimode fibre glass 50 µm (OM2,OM3,OM4, 1310 nm)<br>1 x EtherCAT OUT (Port 2)<br>Electrical: 100Base-TX, 8P8C (“RJ45”), shielded Cat 5, &gt;0.76 μm gold plating</p>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24657</deif:id>
              <deif:guid>91815e7c-5a8e-4460-86e9-a3205b1017a6</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/station-interface/sim63/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The SIM6‧3 has an optical EtherCAT output and 2 RJ45 EtherCAT connections (IN/OUT).</p>]]></deif:description>
              <deif:features><![CDATA[<p>1 x EtherCAT IN (Port 0)<br>Electrical: 100Base-TX, 8P8C (“RJ45”), shielded Cat 5, &gt;0.76 μm gold plating</p>
<p>1 x EtherCAT OUT (Port 1)<br>Optical: 100BASE-FX, SC connectors, multimode fibre glass 50 µm (OM2,OM3,OM4,1310 nm)</p>
<p>1 x EtherCAT OUT (Port 2)<br>Electrical: 100Base-TX, 8P8C (“RJ45”), shielded Cat 5, &gt;0.76 μm gold plating</p>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24658</deif:id>
              <deif:guid>692b392a-b0b0-417e-b891-ff0587943d36</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/station-interface/sim64/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The SIM6‧4 has 2 RJ45 EtherCAT OUT connections.</p>]]></deif:description>
              <deif:features><![CDATA[<p>1 x EtherCAT OUT (Port 1)<br>Electrical: 100Base-TX, 8P8C (""RJ45""), shielded Cat 5, &gt;0.76 μm gold plating</p>
<p>1 x EtherCAT OUT (Port 3)<br>Electrical: 100Base-TX, 8P8C (""RJ45""), shielded Cat 5, &gt;0.76 μm gold plating</p>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>24659</deif:id>
              <deif:guid>028859e8-dcf4-43a8-b791-5a5abe7179cf</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/station-interface/sim65/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The SIM6‧5 has 2 optical EtherCAT OUT connections.</p>]]></deif:description>
              <deif:features><![CDATA[<p>1 x EtherCAT OUT (Port 1) Optical: 100BASE-FX, SC connectors, multi-mode fibre glass 50 μm (OM2, OM3, OM4, 1310 nm)</p>
<p>1 x EtherCAT OUT (Port 2)<br>Optical: 100BASE-FX, SC connectors, multi-mode fibre glass 50 μm (OM2, OM3, OM4, 1310 nm)</p>]]></deif:features>
            </deif:module>
        </deif:modules>
          <item>
            <title>600 series PLC racks Data sheet 4921240694 UK.pdf</title>
            <link>https://deif-cdn-umbraco.azureedge.net/media/ttaceywq/600-series-plc-racks-data-sheet-4921240694-uk.pdf?rnd=134072578163530000&amp;v=9</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/document/6222c084-9dd0-46de-969e-306d97ac220e.xml" type="application/rss+xml" />
            <guid isPermaLink="false">6222c084-9dd0-46de-969e-306d97ac220e</guid>
            <description>600_series_PLC_racks</description>
            <pubDate>Mon, 10 Nov 2025 14:16:56 GMT</pubDate>
            <atom:updated>2025-11-10T14:16:56&#x2B;00:00</atom:updated>
            <dcterms:modified>2025-11-10T14:16:56&#x2B;00:00</dcterms:modified>
            <dcterms:language>eng</dcterms:language>
            <category domain="item-type">document</category>
            <category domain="revision">A</category>
                <category domain="type">Data Sheet</category>
            <enclosure url="https://deif-cdn-umbraco.azureedge.net/media/ttaceywq/600-series-plc-racks-data-sheet-4921240694-uk.pdf?rnd=134072578163530000&amp;v=9" length="3035981" type="application/pdf" />
            <content:encoded><![CDATA[New release]]></content:encoded>
          </item>

  </channel>
</rss>