<?xml version="1.0" encoding="utf-8" ?>

<rss version="2.0"
     xmlns:content="http://purl.org/rss/1.0/modules/content/"
     xmlns:dcterms="http://purl.org/dc/terms/"
     xmlns:atom="http://www.w3.org/2005/Atom"
     xmlns:deif="https://deif.com/rss/product">

  <channel>
    <title>AWC 500</title>
      <link>https://deif-staging.jcdhotel.dk/products/awc-500-advanced-controller/</link>
    <atom:link href="https://deif-staging.jcdhotel.dk/product/16526.xml" rel="self" type="application/rss+xml" />
    <description>Advanced Controller</description>
    <language>en</language>
    <lastBuildDate>Thu, 18 Jun 2026 05:30:18 GMT</lastBuildDate>

        <category domain="product-status">Active</category>
        <deif:key>e3734dae-be5a-4885-a7f3-7cef7b4ee7b7</deif:key>
        <deif:tagline><![CDATA[Advanced Controller]]></deif:tagline>
        <deif:teaser><![CDATA[<p>Robust controller (PLC-based PAC) with extended temperature range</p>]]></deif:teaser>
        <deif:description><![CDATA[<p>The AWC 500 Advanced Controller ( PLC-based PAC ) is the latest addition to our AWC controller series. AWC 500 offers an unprecedented and unrivalled level of robustness.</p>
<p>Not only on mechanical and electrical parameters does the AWC 500 constitute the most robust solution in the industry. The controller is suitable for cold climate or extended temperature operation. With its embedded real-time Linux operational system and CODESYS CONTROL PLC run-time, the AWC 500 also offers a maximum of stability in terms of execution of the application software.</p>
<p><em>*Linux® is the registered trademark of Linus Torvalds in the U.S. and other countries.</em></p>]]></deif:description>
            <deif:features><![CDATA[<ul>
<li>Cold start-up/Operating temperature: -40 to 70°C</li>
<li>Storage temperature: -40 to 85 °</li>
<li>Climate: 55 °C 97 % RH condensing</li>
<li>Altitude: &lt; 4000 m</li>
<li>Vibration : 2.1 g (3.2 to 50 Hz) 1.0g (13.2 to 100 Hz)</li>
<li>Shock: 50 g, 11 ms, half sine</li>
<li>Bump: 25 g, 6 ms, half sine</li>
<li>Direct 3-phase 690 V voltage and 1/5A current measurement, with class 0.5 Power measurement</li>
<li>Fully EtherCAT-based I/O and CAN, SSI, TCP/IP, RS-422/485 communication interfaces</li>
<li>Operating system software with fail-safe update</li>
<li>Fault-tolerant file system</li>
<li>Open software development with Linux, C/C++, CODESYS (IEC 61131-3)</li>
</ul>]]></deif:features>
        <deif:modules>
            <deif:module>
              <deif:id>19806</deif:id>
              <deif:guid>e09d4563-a1c7-49fc-95b9-3e846ef042c8</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/power-and-control-module/pcm5-2/</deif:link>
              <deif:teaser><![CDATA[<p>Extreme temperature (-40 to 70 ºC) 1 GHz dual core ARM Cortex-A7 CPU with real-time patched (PREEMPT_RT) Linux OS</p>]]></deif:teaser>
              <deif:description><![CDATA[<p>Our new top-line processor module for our AWC 500 series is based on the widely used ARM Cortex-A7 embedded SoC. Designed for industrial applications, it offers excessive processing power and fast interfaces for CAN/CANopen, RS-232/485, EtherCAT and Ethernet.</p>]]></deif:description>
              <deif:features><![CDATA[<ul>
<li>50 W power supply with redundant inputs and 20 ms power fail protection. Input range: 18…32 V</li>
<li>1 × digital relay output: 24 V, maximum 1 A resistive</li>
<li>1 × digital input 9…36 V</li>
<li>1 × EtherCAT® OUT electrical (100Base-TX)</li>
<li>1 × EtherCAT® OUT optical (100Base-FX)</li>
<li>2 × Ethernet port (10/100/1000Base-TX)</li>
<li>2 × RS-232/485 port (9.6…460.8 kbit/s, full duplex)</li>
<li>2 × CAN/CANopen</li>
<li>1 × USB 3.0 Host</li>
<li>1 GHz industrial grade 32 bit ARM Cortex-A7 CPU</li>
<li>Embedded real-time Linux operating system</li>
<li>OS image with fail-safe remote update possibility.<br />Power fail-safe, self-monitoring and error correcting file system</li>
<li>Less than 10s startup time (from power-on to fully operational OS)</li>
<li>CODESYS V3.5 Control PLC run-time (option)</li>
<li>CODESYS V3.5 Webvisualization (option)</li>
<li>Memory:</li>
<li>1 GB ECC protected DDR3 RAM (industrial grade)</li>
</ul>
<h4>Application and data storage, non-volatile: </h4>
<ul>
<li>4 GB mSATA, optional up-to 64 GB (Industrial grade)</li>
</ul>
<h4>Storage, removable:</h4>
<ul>
<li>SD card: 2, 4, 8, 16 GB, Up-to 32GB (industrial grade)(option)</li>
</ul>
<h4>Programming:</h4>
<ul>
<li>ANSI C/C++ (GNU C/C++ compiler, Eclipse IDE)    </li>
<li>IEC 61131-3 (IL, SFC, FBD, ST, LD) (option)</li>
</ul>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>19830</deif:id>
              <deif:guid>adcad7c3-4ed5-493a-b357-0ad126d265ed</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/power-and-control-module/pdm5-1/</deif:link>
              <deif:teaser><![CDATA[<p>Power and Distributed communication Module for EtherCat network</p>]]></deif:teaser>
              <deif:description><![CDATA[<p>The PDM5∙1 module is used as a EtherCAT interface for distributed IO nodes via fibre optical Ethernet.</p>]]></deif:description>
              <deif:features><![CDATA[<ul>
<li>Power supply: 50 W with redundant inputs and 50 ms power fail protection. Input range: 18…36 V</li>
<li>1 × digital relay output: 24 V, maximum 1 A resistive</li>
<li>1 × digital input 9...36 V</li>
<li>1 × EtherCAT® OUT electrical (100Base-TX)</li>
<li>1 × EtherCAT® OUT optical (100Base-FX)</li>
<li>1 × EtherCAT® IN optical (100Base-FX)</li>
</ul>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>19834</deif:id>
              <deif:guid>c5217cae-1379-4ffa-8d88-e47b33b4fe9c</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/digital-io/iom5-1/</deif:link>
              <deif:teaser><![CDATA[<p>40 channel multifunction I/O module</p>]]></deif:teaser>
              <deif:description><![CDATA[<p>IOM5∙1 is a highly flexible 40 channel I/O module which features the most commonly used I/O signals in wind power plants. The module is designed for the rough environment in a wind turbine and all inputs and outputs are protected by optical insulation from other potentials.</p>
<p>The IOM5∙1 is equipped with its own processor module, ensuring fast sampling directly on the module and embeds all application-related measurements and scaling. In this way, all measurements are located as a direct part of the process image, thus saving the application time to convert and calculate standard measurements such as rotational speed or acceleration.</p>]]></deif:description>
              <deif:features><![CDATA[<ul>
<li>6 × temperature Pt100/1000 with 2, 3 or 4 wire connection</li>
<li>4 × analogue input, -20…20 mA/-10 V…10 V, resolution 16 bit, accuracy to 0.5%</li>
<li>4 × analogue output, -20…20 mA with configurable ramp time, resolution 12 bit, accuracy to 0.5%</li>
<li>12(16) × digital input, impedance approx. 2.4 kΩ</li>
<li>4(0) × frequency input, range 0…125 kHz, Rotational variables: (time period, acceleration, angle, etc.)</li>
<li>10 × digital output, external supply 9…36 V, output current 0…2 A sink or source (max. 2 A for all output), current limitation for short-circuit or thermal overload</li>
</ul>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>19776</deif:id>
              <deif:guid>08a21bed-fd2d-455c-a011-15550d5d6914</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/digital-io/dim5-1/</deif:link>
              <deif:teaser><![CDATA[<p>46-channel digital I/O module with galvanically separated I/O groups</p>]]></deif:teaser>
              <deif:description><![CDATA[<p>The DIM5∙1 digital I/O module is a dedicated digital I/O module offering 30 digital inputs as well as 16 digital outputs. The 30 digital inputs are divided into four individual, galvanically separated groups (two groups of 8 DIs, two groups of 7 DIs), and the 16 digital outputs are divided into two individual, galvanically separated groups (8 DOs in each).</p>
<p>The module offers current limitation to protect against short-circuits and thermal overload. The status of the protection feature and the external power supply can be monitored. The module has a power consumption of maximum 2W.</p>]]></deif:description>
              <deif:features><![CDATA[<ul>
<li>16 digital outputs(split in two groups with 8 DO in each A and B)</li>
<li>30 digital inputs(split in four groups with 8 DI in groups A and B; and 7 DI in groups C and D)</li>
</ul>
<p> </p>
<p>Digital outputs:</p>
<ul>
<li>12-36V supply</li>
<li>Max current output 500 mA per output</li>
<li>Max current output 2 A per group</li>
</ul>
<p> </p>
<p>Digital inputs:</p>
<ul>
<li>High: ±9 to 36V with reference to common</li>
<li>Low: ±5 V with reference to common</li>
</ul>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>19781</deif:id>
              <deif:guid>2593d7f5-8e8a-4c2b-a79c-82c2875f8e91</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/grid-protection-modules/gpm5-1/</deif:link>
              <deif:teaser><![CDATA[<p>Grid Protection Module</p>]]></deif:teaser>
              <deif:description><![CDATA[<p>The GPM5∙1 module is a class 0.5 grid measurements and protection module, fully configurable from the main application. The module has an onboard processor for sampling of grid measurements such as three-phase voltages, currents, phase angles and power vector measurements. The availability of these measurements/calculations as variables takes load from the application, thus making it faster. The GPM5∙1 module enables the application to read the following values directly from the process image, thus reducing the processing time of the application.</p>
<p>A special feature of the GPM5∙1 card is that it has a true class 0.5 calculation, also on power measurements. The module features class 0.5 measurements of voltage, frequency, current, power, reactive power and phase angle</p>]]></deif:description>
              <deif:features><![CDATA[<p>Inputs&nbsp;</p>
<ul>
<li>2 x direct three phase voltage inputs (L1, L2, L3, N)</li>
<li>Input range: 0 to 690 V</li>
<li>Measure range: 40 to 690 V</li>
<li>Frequency: 40 to 70 Hz</li>
<li>Load max.: 0.5 mA or 0.3 VA per phase</li>
<li>Overload: 130 % continuously, 200 % for 10 s</li>
<li>External fuse, maximum 2 A slow-blow</li>
<li>UL/cUL: Maximum 600 V L-L, above 2000 m altitude maximum 520 V<br><br></li>
<li>1 x direct three phase current input (L1, L2, L3)&nbsp;</li>
<li>Input range: 0 to 1 or 0 to 5 A</li>
<li>Frequency: 40 to 70 Hz</li>
<li>Load max.: 0.4 VA per phase</li>
<li>Overload: 20 A for 60 s, &lt; 75 A for 10 s, &lt; 300 A for 1 s</li>
<li>UL/cUL: From listed or R/C (XODW2.8) current transformers</li>
</ul>
<p>Outputs</p>
<ul>
<li>2 x digital relay outputs (normally open) with feedback supervision</li>
<li>24 V, maximum 1 A resistive</li>
</ul>
<p>Certification class</p>
<ul>
<li>0.5 measurement of voltage, frequency, current, power, reactive power, phase angle.</li>
</ul>
<p>Galvanic separation</p>
<ul>
<li>3.25 kV 50 Hz isolation between voltage measurement inputs individually and between voltage measurement inputs and all other potentials.</li>
<li>550 V 50 Hz isolation between relay outputs, digital inputs (feedback supervision) and all other potentials.</li>
</ul>
<p>Safety</p>
<ul>
<li>Installation (over-voltage) category III, 600 V, pollution degree 2.<br><br></li>
<li>EN 61010-1 tested at 50 Hz, 60 s.</li>
<li>Each galvanic group tested to other galvanic groups and to Protective Earth, PE.</li>
</ul>
<p>Accuracy</p>
<ul>
<li>0.5 % at reference temperatures</li>
<li>1.0 % at operational temperatures</li>
<li>IEC 60688</li>
</ul>
<p>Size</p>
<ul>
<li>6 TE (30.48 mm)</li>
</ul>
<p>Power consumption</p>
<ul>
<li>Maximum 4 W</li>
</ul>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>19840</deif:id>
              <deif:guid>f817e338-0b33-44bf-9241-85c7ed5d2cc5</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/communication-modules/ifm5-2/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The IFM5∙2 is an industrial grade Ethernet switch with extreme robustness and operation temperature range.</p>
<p>The IFM5∙2 can serve as a media converter module, securing galvanic isolation of networks in the wind turbine and to<br />external networks.</p>
<p>IFM5∙2 offers an advanced, yet simple to use, ring-protection feature which is much faster and more reliable than normally used network equipment in wind turbines and other industrial systems.</p>
<p>The technology behind this feature is the ERPS standard, which is normally used in high-end back-bone switches at professional network operators/providers.</p>
<p>This means that in case of for example cable breaks, the recovery time is much faster than "‘standard ring-switches".</p>
<p>The IFM5∙2 has full support for Virtual LAN configuration (VLAN) in accordance with IEEE 802.1Q and is fully configurable from the application running on the processor module (PCM5∙x).</p>
<p>It furthermore supports Ethernet over EtherCAT (EoE), ensuring full distributed integration of the modules, allowing Ethernet to be available at any position in the wind turbine without additional fibre connections.</p>
<div>​</div>]]></deif:description>
              <deif:features><![CDATA[<p>LAN ports</p>
<ul>
<li>1 x Ethernet (Port 4) optical:</li>
<li>100Base-FX, SC connectors, multimode fibre 62,5 μm, OM1</li>
<li>1 x Ethernet (Port 3) electrical:</li>
<li>100Base-TX, 8P8C (“RJ45”), shielded Cat5, &gt;0.76 µm gold plating</li>
<li>1 x Ethernet (Port 2) electrical:</li>
<li>100Base-TX, 8P8C (“RJ45”), shielded Cat5, &gt;0.76 µm gold plating</li>
<li>1 x Ethernet (Port 1) electrical:</li>
<li>100Base-TX, 8P8C (“RJ45”), shielded Cat5, &gt;0.76 µm gold plating</li>
</ul>
<p>Size </p>
<ul>
<li>6 TE (30.48 mm)</li>
</ul>
<p>Power consumption </p>
<ul>
<li>Maximum 4 W</li>
</ul>]]></deif:features>
            </deif:module>
            <deif:module>
              <deif:id>19778</deif:id>
              <deif:guid>14e1dd43-3f36-4519-a727-c49b6d0e90f8</deif:guid>
              <deif:link>https://deif-staging.jcdhotel.dk/products/modules/communication-modules/ifm5-1/</deif:link>
              <deif:teaser><![CDATA[]]></deif:teaser>
              <deif:description><![CDATA[<p>The IFM5∙1 interface and fieldbus module offers RS-485/422, SSI and CAN interfaces.</p>]]></deif:description>
              <deif:features><![CDATA[<p>2 RS-485/422 interfaces </p>
<ul>
<li>Standards: TIA/EIA-485 ANSI/TIA/EIA-422-B</li>
<li>Baud rate: 9.6, 19.2, 38.4, 57.6, 115.2, 230.4, 460.8 or 921.6 kbit/s</li>
<li>Word length: 5, 6, 7 or 8 bits</li>
<li>Parity: None, even, odd, mark or space</li>
<li>Stop bits: 1 or 2</li>
<li>Flow control: None</li>
<li>Biasing: On or off</li>
<li>Communication lines: 4 wire full duplex or 2 wire half duplex</li>
<li>Isolation: Optically isolated from other potentials, 550 V 50 Hz.</li>
</ul>
<p>2 CAN interfaces</p>
<ul>
<li>Standards: ISO 11898</li>
<li>Baud rate: 20, 50, 125, 250, 500, 800 or 1000 kbit/s sample point at 80 to 87.5 %</li>
<li>Isolation: Optically isolated from other potentials, 550 V 50 Hz.</li>
</ul>
<p>2 SSI interfaces</p>
<ul>
<li>Standards: Synchronous Serial Interface, SSI, Stegmann Interface ANSI/TIA/EIA-422-B</li>
<li>Baud rate: 125, 250, 500, 1000, 1250 or 1500 kbit/s</li>
<li>Word length: 8 to 32 bits</li>
<li>Data delay: Configurable: 0.04 to 50 ms</li>
<li>Coding: Binary or Gray code</li>
<li>Frame error suppression: Yes or no</li>
<li>Isolation: As a group, SSI is optically isolated from other potentials, 550 V 50 Hz.</li>
<li>SSI device supply: 24 V, maximum 100 mA per channel/device.</li>
<li>SSI power supply: input 18 to 36 V, maximum 1 A</li>
</ul>
<p>Size</p>
<ul>
<li>6 TE (30.48 mm)</li>
</ul>
<p>Power consumption</p>
<ul>
<li>Maximum 4 W</li>
</ul>]]></deif:features>
            </deif:module>
        </deif:modules>
          <item>
            <title>General safety note 4189341189 UK-FR.pdf</title>
            <link>https://deif-cdn-umbraco.azureedge.net/media/t3ofzpjw/general-safety-note-4189341189-uk-fr.pdf?rnd=134045044194400000&amp;v=9</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/document/bd5c5d87-9036-4df9-881e-cc1bd5ed3b40.xml" type="application/rss+xml" />
            <guid isPermaLink="false">bd5c5d87-9036-4df9-881e-cc1bd5ed3b40</guid>
            <description>MDR-2</description>
            <pubDate>Thu, 09 Oct 2025 17:26:59 GMT</pubDate>
            <atom:updated>2025-10-09T17:26:59&#x2B;00:00</atom:updated>
            <dcterms:modified>2025-10-09T17:26:59&#x2B;00:00</dcterms:modified>
            <dcterms:language>eng</dcterms:language>
            <category domain="item-type">document</category>
            <category domain="revision">C</category>
                <category domain="type">Other Technical Documentation</category>
            <enclosure url="https://deif-cdn-umbraco.azureedge.net/media/t3ofzpjw/general-safety-note-4189341189-uk-fr.pdf?rnd=134045044194400000&amp;v=9" length="685328" type="application/pdf" />
            <content:encoded><![CDATA[New DEIF branding]]></content:encoded>
          </item>
          <item>
            <title>AWC 500 &#x6570;&#x636E;&#x4E2D;&#x5FC3;&#x5E94;&#x7528; &#x4E2D;&#x6587;.pdf</title>
            <link>https://deif-cdn-umbraco.azureedge.net/media/zegl2q4n/awc-500-&#x6570;&#x636E;&#x4E2D;&#x5FC3;&#x5E94;&#x7528;-&#x4E2D;&#x6587;.pdf?rnd=133845133233730000&amp;v=9</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/document/43be0dd1-48cd-4733-b30e-b5489051b2f6.xml" type="application/rss+xml" />
            <guid isPermaLink="false">43be0dd1-48cd-4733-b30e-b5489051b2f6</guid>
            <description>AWC_500</description>
            <pubDate>Thu, 20 Feb 2025 08:22:03 GMT</pubDate>
            <atom:updated>2025-02-20T08:22:03&#x2B;00:00</atom:updated>
            <dcterms:modified>2025-02-20T08:22:03&#x2B;00:00</dcterms:modified>
            <dcterms:language>zho</dcterms:language>
            <category domain="item-type">document</category>
            <category domain="revision">B</category>
                <category domain="type">Brochures/Handouts</category>
            <enclosure url="https://deif-cdn-umbraco.azureedge.net/media/zegl2q4n/awc-500-&#x6570;&#x636E;&#x4E2D;&#x5FC3;&#x5E94;&#x7528;-&#x4E2D;&#x6587;.pdf?rnd=133845133233730000&amp;v=9" length="933459" type="application/pdf" />
            <content:encoded><![CDATA[Updated Address]]></content:encoded>
          </item>
          <item>
            <title>CODESYS Guidelines for AMC 300, AMC 600, AWC 500, iE 250 4189341353 UK.pdf</title>
            <link>https://deif-cdn-umbraco.azureedge.net/media/tnrgl2pt/codesys-guidelines-for-amc-300-amc-600-awc-500-ie-250-4189341353-uk.pdf?rnd=133688813143630000&amp;v=9</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/document/f1656283-def3-45ff-94dd-c9158d91b9e2.xml" type="application/rss+xml" />
            <guid isPermaLink="false">f1656283-def3-45ff-94dd-c9158d91b9e2</guid>
            <description>AMC_300</description>
            <pubDate>Fri, 23 Aug 2024 10:08:34 GMT</pubDate>
            <atom:updated>2024-08-23T10:08:34&#x2B;00:00</atom:updated>
            <dcterms:modified>2024-08-23T10:08:34&#x2B;00:00</dcterms:modified>
            <dcterms:language>eng</dcterms:language>
            <category domain="item-type">document</category>
            <category domain="revision">A</category>
                <category domain="type">User&#x27;s Manual</category>
            <enclosure url="https://deif-cdn-umbraco.azureedge.net/media/tnrgl2pt/codesys-guidelines-for-amc-300-amc-600-awc-500-ie-250-4189341353-uk.pdf?rnd=133688813143630000&amp;v=9" length="16484652" type="application/pdf" />
            <content:encoded><![CDATA[]]></content:encoded>
          </item>
          <item>
            <title>AWC 500 Critical Power Applications.pdf (1)</title>
            <link>https://deif-cdn-umbraco.azureedge.net/media/isqlbcpb/awc-500-critical-power-applications.pdf?rnd=133578925413130000&amp;v=9</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/document/89a0a15c-90e1-4cd6-8502-f870fd70fe79.xml" type="application/rss+xml" />
            <guid isPermaLink="false">89a0a15c-90e1-4cd6-8502-f870fd70fe79</guid>
            <description>AWC_500</description>
            <pubDate>Thu, 18 Apr 2024 05:42:21 GMT</pubDate>
            <atom:updated>2024-04-18T05:42:21&#x2B;00:00</atom:updated>
            <dcterms:modified>2024-04-18T05:42:21&#x2B;00:00</dcterms:modified>
            <dcterms:language>eng</dcterms:language>
            <category domain="item-type">document</category>
            <category domain="revision">A</category>
                <category domain="type">Brochures/Handouts</category>
            <enclosure url="https://deif-cdn-umbraco.azureedge.net/media/isqlbcpb/awc-500-critical-power-applications.pdf?rnd=133578925413130000&amp;v=9" length="0" type="application/pdf" />
            <content:encoded><![CDATA[]]></content:encoded>
          </item>
          <item>
            <title>UL E314309 20121109 UK.pdf</title>
            <link>https://deif-cdn-umbraco.azureedge.net/media/5vpjbx3o/ul-e314309-20121109-uk.pdf?rnd=133578925384730000&amp;v=9</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/document/df905ee5-31ae-4d7d-9906-b0574af95b13.xml" type="application/rss+xml" />
            <guid isPermaLink="false">df905ee5-31ae-4d7d-9906-b0574af95b13</guid>
            <description>AWC_500</description>
            <pubDate>Thu, 18 Apr 2024 05:42:18 GMT</pubDate>
            <atom:updated>2024-04-18T05:42:18&#x2B;00:00</atom:updated>
            <dcterms:modified>2024-04-18T05:42:18&#x2B;00:00</dcterms:modified>
            <dcterms:language>eng</dcterms:language>
            <category domain="item-type">document</category>
            <category domain="revision">A</category>
                <category domain="type">Approvals/Certifications</category>
            <enclosure url="https://deif-cdn-umbraco.azureedge.net/media/5vpjbx3o/ul-e314309-20121109-uk.pdf?rnd=133578925384730000&amp;v=9" length="0" type="application/pdf" />
            <content:encoded><![CDATA[]]></content:encoded>
          </item>
          <item>
            <title>AWC 500 Installation instructions 4189340734_UK.pdf</title>
            <link>https://deif-cdn-umbraco.azureedge.net/media/b4ybc1qn/awc-500-installation-instructions-4189340734_uk.pdf?rnd=133578925274100000&amp;v=9</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/document/6e01b117-ec0d-4598-8364-9b9bf226a86b.xml" type="application/rss+xml" />
            <guid isPermaLink="false">6e01b117-ec0d-4598-8364-9b9bf226a86b</guid>
            <description>AWC_500</description>
            <pubDate>Thu, 18 Apr 2024 05:42:07 GMT</pubDate>
            <atom:updated>2024-04-18T05:42:07&#x2B;00:00</atom:updated>
            <dcterms:modified>2024-04-18T05:42:07&#x2B;00:00</dcterms:modified>
            <dcterms:language>eng</dcterms:language>
            <category domain="item-type">document</category>
            <category domain="revision">B</category>
                <category domain="type">Installation Instructions</category>
            <enclosure url="https://deif-cdn-umbraco.azureedge.net/media/b4ybc1qn/awc-500-installation-instructions-4189340734_uk.pdf?rnd=133578925274100000&amp;v=9" length="0" type="application/pdf" />
            <content:encoded><![CDATA[]]></content:encoded>
          </item>
          <item>
            <title>AWC 500 Getting started 4189340733_UK.pdf</title>
            <link>https://deif-cdn-umbraco.azureedge.net/media/crpcccil/awc-500-getting-started-4189340733_uk.pdf?rnd=133578925204200000&amp;v=9</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/document/09215e0c-4c0b-4284-b19a-eb97795f6035.xml" type="application/rss+xml" />
            <guid isPermaLink="false">09215e0c-4c0b-4284-b19a-eb97795f6035</guid>
            <description>AWC_500</description>
            <pubDate>Thu, 18 Apr 2024 05:42:00 GMT</pubDate>
            <atom:updated>2024-04-18T05:42:00&#x2B;00:00</atom:updated>
            <dcterms:modified>2024-04-18T05:42:00&#x2B;00:00</dcterms:modified>
            <dcterms:language>eng</dcterms:language>
            <category domain="item-type">document</category>
            <category domain="revision">G</category>
                <category domain="type">User&#x27;s Manual</category>
            <enclosure url="https://deif-cdn-umbraco.azureedge.net/media/crpcccil/awc-500-getting-started-4189340733_uk.pdf?rnd=133578925204200000&amp;v=9" length="0" type="application/pdf" />
            <content:encoded><![CDATA[]]></content:encoded>
          </item>
          <item>
            <title>AWC 500 CODESYS Development Package 4189340814_UK.pdf</title>
            <link>https://deif-cdn-umbraco.azureedge.net/media/h5ldk1d1/awc-500-codesys-development-package-4189340814_uk.pdf?rnd=133578925168400000&amp;v=9</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/document/6c35d727-b47b-4227-a58a-bc6262e3f0dd.xml" type="application/rss+xml" />
            <guid isPermaLink="false">6c35d727-b47b-4227-a58a-bc6262e3f0dd</guid>
            <description>AWC_500</description>
            <pubDate>Thu, 18 Apr 2024 05:41:56 GMT</pubDate>
            <atom:updated>2024-04-18T05:41:56&#x2B;00:00</atom:updated>
            <dcterms:modified>2024-04-18T05:41:56&#x2B;00:00</dcterms:modified>
            <dcterms:language>eng</dcterms:language>
            <category domain="item-type">document</category>
            <category domain="revision">D</category>
                <category domain="type">User&#x27;s Manual</category>
            <enclosure url="https://deif-cdn-umbraco.azureedge.net/media/h5ldk1d1/awc-500-codesys-development-package-4189340814_uk.pdf?rnd=133578925168400000&amp;v=9" length="0" type="application/pdf" />
            <content:encoded><![CDATA[]]></content:encoded>
          </item>
          <item>
            <title>AWC 500 System description 4189340735_UK.pdf</title>
            <link>https://deif-cdn-umbraco.azureedge.net/media/rgtdat5u/awc-500-system-description-4189340735_uk.pdf?rnd=133578925100400000&amp;v=9</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/document/4f30a691-e5f4-4566-942b-ad444fc45772.xml" type="application/rss+xml" />
            <guid isPermaLink="false">4f30a691-e5f4-4566-942b-ad444fc45772</guid>
            <description>AWC_500</description>
            <pubDate>Thu, 18 Apr 2024 05:41:50 GMT</pubDate>
            <atom:updated>2024-04-18T05:41:50&#x2B;00:00</atom:updated>
            <dcterms:modified>2024-04-18T05:41:50&#x2B;00:00</dcterms:modified>
            <dcterms:language>eng</dcterms:language>
            <category domain="item-type">document</category>
            <category domain="revision">B</category>
                <category domain="type">Other Technical Documentation</category>
            <enclosure url="https://deif-cdn-umbraco.azureedge.net/media/rgtdat5u/awc-500-system-description-4189340735_uk.pdf?rnd=133578925100400000&amp;v=9" length="0" type="application/pdf" />
            <content:encoded><![CDATA[]]></content:encoded>
          </item>
          <item>
            <title>AWC 500 Handout UK.pdf</title>
            <link>https://deif-cdn-umbraco.azureedge.net/media/0huh3dre/awc-500-handout-uk.pdf?rnd=133578924916470000&amp;v=9</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/document/8e7ee8c9-cb24-4134-bb74-cd2f64dd1df1.xml" type="application/rss+xml" />
            <guid isPermaLink="false">8e7ee8c9-cb24-4134-bb74-cd2f64dd1df1</guid>
            <description>AWC_500</description>
            <pubDate>Thu, 18 Apr 2024 05:41:31 GMT</pubDate>
            <atom:updated>2024-04-18T05:41:31&#x2B;00:00</atom:updated>
            <dcterms:modified>2024-04-18T05:41:31&#x2B;00:00</dcterms:modified>
            <dcterms:language>eng</dcterms:language>
            <category domain="item-type">document</category>
            <category domain="revision">B</category>
                <category domain="type">Brochures/Handouts</category>
            <enclosure url="https://deif-cdn-umbraco.azureedge.net/media/0huh3dre/awc-500-handout-uk.pdf?rnd=133578924916470000&amp;v=9" length="0" type="application/pdf" />
            <content:encoded><![CDATA[]]></content:encoded>
          </item>
          <item>
            <title>PCM5-2 Handout UK.pdf</title>
            <link>https://deif-cdn-umbraco.azureedge.net/media/k3cfhdfx/pcm5-2-handout-uk.pdf?rnd=133578924849870000&amp;v=9</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/document/8c53454f-14b7-40a5-b665-c946962822aa.xml" type="application/rss+xml" />
            <guid isPermaLink="false">8c53454f-14b7-40a5-b665-c946962822aa</guid>
            <description>AWC_500</description>
            <pubDate>Thu, 18 Apr 2024 05:41:24 GMT</pubDate>
            <atom:updated>2024-04-18T05:41:24&#x2B;00:00</atom:updated>
            <dcterms:modified>2024-04-18T05:41:24&#x2B;00:00</dcterms:modified>
            <dcterms:language>eng</dcterms:language>
            <category domain="item-type">document</category>
            <category domain="revision">B</category>
                <category domain="type">Brochures/Handouts</category>
            <enclosure url="https://deif-cdn-umbraco.azureedge.net/media/k3cfhdfx/pcm5-2-handout-uk.pdf?rnd=133578924849870000&amp;v=9" length="0" type="application/pdf" />
            <content:encoded><![CDATA[]]></content:encoded>
          </item>
          <item>
            <title>AxC 500 External C codesys libraries 4189340767 UK.pdf</title>
            <link>https://deif-cdn-umbraco.azureedge.net/media/cf4b3ymg/axc-500-external-c-codesys-libraries-4189340767-uk.pdf?rnd=133578923832500000&amp;v=9</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/document/e10e7d09-f786-4343-8ed9-ff773e73d14f.xml" type="application/rss+xml" />
            <guid isPermaLink="false">e10e7d09-f786-4343-8ed9-ff773e73d14f</guid>
            <description>PMC</description>
            <pubDate>Thu, 18 Apr 2024 05:39:43 GMT</pubDate>
            <atom:updated>2024-04-18T05:39:43&#x2B;00:00</atom:updated>
            <dcterms:modified>2024-04-18T05:39:43&#x2B;00:00</dcterms:modified>
            <dcterms:language>eng</dcterms:language>
            <category domain="item-type">document</category>
            <category domain="revision">C</category>
                <category domain="type">Operator&#x27;s Manual</category>
            <enclosure url="https://deif-cdn-umbraco.azureedge.net/media/cf4b3ymg/axc-500-external-c-codesys-libraries-4189340767-uk.pdf?rnd=133578923832500000&amp;v=9" length="0" type="application/pdf" />
            <content:encoded><![CDATA[]]></content:encoded>
          </item>
          <item>
            <title>AWC 500 Data sheet 4921240395 UK.pdf</title>
            <link>https://deif-cdn-umbraco.azureedge.net/media/au2ip0m4/awc-500-data-sheet-4921240395-uk.pdf?rnd=133578923510730000&amp;v=9</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/document/e987381d-b69e-43d7-a56b-d7f68fb3e706.xml" type="application/rss+xml" />
            <guid isPermaLink="false">e987381d-b69e-43d7-a56b-d7f68fb3e706</guid>
            <description>PMC</description>
            <pubDate>Thu, 18 Apr 2024 05:39:11 GMT</pubDate>
            <atom:updated>2024-04-18T05:39:11&#x2B;00:00</atom:updated>
            <dcterms:modified>2024-04-18T05:39:11&#x2B;00:00</dcterms:modified>
            <dcterms:language>eng</dcterms:language>
            <category domain="item-type">document</category>
            <category domain="revision">I</category>
                <category domain="type">Data Sheet</category>
            <enclosure url="https://deif-cdn-umbraco.azureedge.net/media/au2ip0m4/awc-500-data-sheet-4921240395-uk.pdf?rnd=133578923510730000&amp;v=9" length="0" type="application/pdf" />
            <content:encoded><![CDATA[New styesheet applied and new front cover (rev I). March 2024.]]></content:encoded>
          </item>
          <item>
            <title>UKCA DoC 4910290582 UK.pdf</title>
            <link>https://deif-cdn-umbraco.azureedge.net/media/j0ghdej5/ukca-doc-4910290582-uk.pdf?rnd=133578923079630000&amp;v=9</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/document/91618d56-353f-454b-9fbb-6619b8b1676e.xml" type="application/rss+xml" />
            <guid isPermaLink="false">91618d56-353f-454b-9fbb-6619b8b1676e</guid>
            <description>PMC</description>
            <pubDate>Thu, 18 Apr 2024 05:38:27 GMT</pubDate>
            <atom:updated>2024-04-18T05:38:27&#x2B;00:00</atom:updated>
            <dcterms:modified>2024-04-18T05:38:27&#x2B;00:00</dcterms:modified>
            <dcterms:language>eng</dcterms:language>
            <category domain="item-type">document</category>
            <category domain="revision">A</category>
                <category domain="type">Approvals/Certifications</category>
            <enclosure url="https://deif-cdn-umbraco.azureedge.net/media/j0ghdej5/ukca-doc-4910290582-uk.pdf?rnd=133578923079630000&amp;v=9" length="0" type="application/pdf" />
            <content:encoded><![CDATA[]]></content:encoded>
          </item>
          <item>
            <title>CE DoC 4910290082 UK.pdf</title>
            <link>https://deif-cdn-umbraco.azureedge.net/media/t2ff0spa/ce-doc-4910290082-uk.pdf?rnd=133578922707130000&amp;v=9</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/document/494d0b87-1de0-4829-a8e6-f88c8bf6ec4c.xml" type="application/rss+xml" />
            <guid isPermaLink="false">494d0b87-1de0-4829-a8e6-f88c8bf6ec4c</guid>
            <description>PMC</description>
            <pubDate>Thu, 18 Apr 2024 05:37:50 GMT</pubDate>
            <atom:updated>2024-04-18T05:37:50&#x2B;00:00</atom:updated>
            <dcterms:modified>2024-04-18T05:37:50&#x2B;00:00</dcterms:modified>
            <dcterms:language>eng</dcterms:language>
            <category domain="item-type">document</category>
            <category domain="revision">F</category>
                <category domain="type">Approvals/Certifications</category>
            <enclosure url="https://deif-cdn-umbraco.azureedge.net/media/t2ff0spa/ce-doc-4910290082-uk.pdf?rnd=133578922707130000&amp;v=9" length="0" type="application/pdf" />
            <content:encoded><![CDATA[]]></content:encoded>
          </item>
          <item>
            <title>AWC 500 CODESYS TSP (SP15 Patch 20) - v1.3.0.8</title>
            <link>https://deif-staging.jcdhotel.dk/software/awc-500-codesys-tsp-sp15-patch-20/1-3-0-8/</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/software/16888.xml" type="application/rss+xml" />
            <guid isPermaLink="true">87c08357-5dd4-416a-971d-5c0b976f3caf</guid>
            <pubDate>2023-08-08T00:00:00&#x2B;00:00</pubDate>
            <category domain="item-type">software-version</category>
            <category domain="software">AWC 500 CODESYS TSP (SP15 Patch 20)</category>
            <category domain="version">1.3.0.8</category>
            <category domain="release-status">current</category>
                    <content:encoded><![CDATA[<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.15.20</p>
<p> </p>
<p><strong>Added</strong></p>
<ul>
<li>CODESYS OPC UA Server (SP18 and newer)</li>
<li>Updated IFM61 devdesc to v1.1.0.0, revision 9</li>
<li>Updated CMM62 devdesc to v0.9.0.2, revision 2</li>
<li>Updated SIM61 devdesc to v1.0.0.1, revision 2</li>
<li>Updated SIM62 devdesc to v1.0.0.0, revision 2</li>
<li>Updated SIM63 devdesc to v1.0.0.1, revision 2</li>
<li>Added DOM61 devdesc to v0.2.0.0, revision 2</li>
<li>Added DIM61 devdesc to v0.1.0.0, revision 1</li>
<li>Added DIO62 devdesc to v0.1.0.0, revision 1</li>
</ul>
<p> </p>
<p><strong>Corrections</strong></p>
<ul>
<li>Renamed CMM62 devdesc to v1.0.0.0 to v0.9.0.1, revision 1</li>
<li>Fix scan/copy all devices SIM6.2</li>
</ul>]]></content:encoded>
          </item>
          <item>
            <title>AWC 500 CODESYS run-time (SP15 Patch 20) for PCM5.2 - v1.3.0.8</title>
            <link>https://deif-staging.jcdhotel.dk/software/awc-500-codesys-run-time-sp15-patch-20-for-pcm52/1-3-0-8/</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/software/16913.xml" type="application/rss+xml" />
            <guid isPermaLink="true">9eef3109-1b39-4aea-8a1d-e19c8c07e3b8</guid>
            <pubDate>2023-08-08T00:00:00&#x2B;00:00</pubDate>
            <category domain="item-type">software-version</category>
            <category domain="software">AWC 500 CODESYS run-time (SP15 Patch 20) for PCM5.2</category>
            <category domain="version">1.3.0.8</category>
            <category domain="release-status">current</category>
                    <content:encoded><![CDATA[<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.15.20</p>
<p> </p>
<p><strong>Added</strong></p>
<ul>
<li>CODESYS OPC UA Server (SP18 and newer)</li>
<li>Updated IFM61 devdesc to v1.1.0.0, revision 9</li>
<li>Updated CMM62 devdesc to v0.9.0.2, revision 2</li>
<li>Updated SIM61 devdesc to v1.0.0.1, revision 2</li>
<li>Updated SIM62 devdesc to v1.0.0.0, revision 2</li>
<li>Updated SIM63 devdesc to v1.0.0.1, revision 2</li>
<li>Added DOM61 devdesc to v0.2.0.0, revision 2</li>
<li>Added DIM61 devdesc to v0.1.0.0, revision 1</li>
<li>Added DIO62 devdesc to v0.1.0.0, revision 1</li>
</ul>
<p> </p>
<p><strong>Corrections</strong></p>
<ul>
<li>Renamed CMM62 devdesc to v1.0.0.0 to v0.9.0.1, revision 1</li>
<li>Fix scan/copy all devices SIM6.2</li>
</ul>]]></content:encoded>
          </item>
          <item>
            <title>AWC 500 CODESYS TSP (SP18 Patch 40) - v1.3.0.8</title>
            <link>https://deif-staging.jcdhotel.dk/software/awc-500-codesys-tsp-sp18-patch-40/1-3-0-8/</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/software/16965.xml" type="application/rss+xml" />
            <guid isPermaLink="true">671e1e7e-8190-4f4a-a906-c07b1408ade9</guid>
            <pubDate>2023-07-31T00:00:00&#x2B;00:00</pubDate>
            <category domain="item-type">software-version</category>
            <category domain="software">AWC 500 CODESYS TSP (SP18 Patch 40)</category>
            <category domain="version">1.3.0.8</category>
            <category domain="release-status">current</category>
                    <content:encoded><![CDATA[<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.18.40</p>
<p> </p>
<p><strong>Added</strong></p>
<ul>
<li>CODESYS OPC UA Server (SP18 and newer)</li>
<li>Updated IFM61 devdesc to v1.1.0.0, revision 9</li>
<li>Updated CMM62 devdesc to v0.9.0.2, revision 2</li>
<li>Updated SIM61 devdesc to v1.0.0.1, revision 2</li>
<li>Updated SIM62 devdesc to v1.0.0.0, revision 2</li>
<li>Updated SIM63 devdesc to v1.0.0.1, revision 2</li>
<li>Added DOM61 devdesc to v0.2.0.0, revision 2</li>
<li>Added DIM61 devdesc to v0.1.0.0, revision 1</li>
<li>Added DIO62 devdesc to v0.1.0.0, revision 1</li>
</ul>
<p> </p>
<p><strong>Corrections</strong></p>
<ul>
<li>Renamed CMM62 devdesc to v1.0.0.0 to v0.9.0.1, revision 1</li>
<li>Fix scan/copy all devices SIM6.2</li>
</ul>]]></content:encoded>
          </item>
          <item>
            <title>AWC 500 CODESYS run-time (SP18 Patch 40) for PCM5.2 - v1.3.0.8</title>
            <link>https://deif-staging.jcdhotel.dk/software/awc-500-codesys-run-time-sp18-patch-40-for-pcm52/1-3-0-8/</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/software/16967.xml" type="application/rss+xml" />
            <guid isPermaLink="true">c09f938f-f93d-4f32-8ffc-cf11956c796d</guid>
            <pubDate>2023-07-31T00:00:00&#x2B;00:00</pubDate>
            <category domain="item-type">software-version</category>
            <category domain="software">AWC 500 CODESYS run-time (SP18 Patch 40) for PCM5.2</category>
            <category domain="version">1.3.0.8</category>
            <category domain="release-status">current</category>
                    <content:encoded><![CDATA[<p>Run-time software for CODESYS on a PCM5.2 board</p>
<p>This version relates specific to CODESYS ver. 3.5.18.40</p>
<p> </p>
<p><strong>Added</strong></p>
<ul>
<li>- CODESYS OPC UA Server (SP18 and newer)</li>
<li>Updated IFM61 devdesc to v1.1.0.0, revision 9</li>
<li>Updated CMM62 devdesc to v0.9.0.2, revision 2</li>
<li>Updated SIM61 devdesc to v1.0.0.1, revision 2</li>
<li>Updated SIM62 devdesc to v1.0.0.0, revision 2</li>
<li>Updated SIM63 devdesc to v1.0.0.1, revision 2</li>
<li>Added DOM61 devdesc to v0.2.0.0, revision 2</li>
<li>Added DIM61 devdesc to v0.1.0.0, revision 1</li>
<li>Added DIO62 devdesc to v0.1.0.0, revision 1</li>
</ul>
<p> </p>
<p><strong>Corrections</strong></p>
<ul>
<li>Renamed CMM62 devdesc to v1.0.0.0 to v0.9.0.1, revision 1</li>
<li>Fix scan/copy all devices SIM6.2</li>
</ul>]]></content:encoded>
          </item>
          <item>
            <title>AWC 500 PCM5.2 software bundle (CODESYS SP15 Patch 20) - v3.0.7.1</title>
            <link>https://deif-staging.jcdhotel.dk/software/awc-500-pcm52-software-bundle-codesys-sp15-patch-20/3-0-7-1/</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/software/16940.xml" type="application/rss+xml" />
            <guid isPermaLink="true">ee8ea6f0-7758-4b91-90e4-3ac22434b09f</guid>
            <pubDate>2025-04-10T00:00:00&#x2B;00:00</pubDate>
            <category domain="item-type">software-version</category>
            <category domain="software">AWC 500 PCM5.2 software bundle (CODESYS SP15 Patch 20)</category>
            <category domain="version">3.0.7.1</category>
            <category domain="release-status">current</category>
                    <content:encoded><![CDATA[<p>This release contains minor corrections and changes.</p>
<h3>Corrections</h3>
<ul>
<li>Bug causing link loss on EoE interfaces after EtherCAT rescan.</li>
<li>Fixed module list on the web interface.</li>
<li>Fixed selection of the time zone "(GMT-08:00) Pacific Time (US &amp; Canada)" in the web interface.</li>
<li>Problem with logc tail -f not showing new log lines.</li>
<li>Bug causing logc cat to fail with "too many open files" fail, and consequently also web interface syslog.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Updated to bingbang v1.0.2.0.</li>
</ul>]]></content:encoded>
          </item>
          <item>
            <title>AWC 500 PCM5.2 Linux SDK - v3.0.7.1</title>
            <link>https://deif-staging.jcdhotel.dk/software/awc-500-pcm52-linux-sdk/3-0-7-1/</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/software/24790.xml" type="application/rss+xml" />
            <guid isPermaLink="true">c2d6fa94-916d-40c5-9aab-dda3579b5e0a</guid>
            <pubDate>2025-12-16T00:00:00&#x2B;00:00</pubDate>
            <category domain="item-type">software-version</category>
            <category domain="software">AWC 500 PCM5.2 Linux SDK</category>
            <category domain="version">3.0.7.1</category>
            <category domain="release-status">current</category>
                    <content:encoded><![CDATA[<p>This release contains minor corrections and changes.</p>
<h3>Corrections</h3>
<ul>
<li>Bug causing link loss on EoE interfaces after EtherCAT rescan.</li>
<li>Fixed module list on the web interface.</li>
<li>Fixed selection of the time zone "(GMT-08:00) Pacific Time (US &amp; Canada)" in the web interface.</li>
<li>Problem with logc tail -f not showing new log lines.</li>
<li>Bug causing logc cat to fail with "too many open files" fail, and consequently also web interface syslog.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Updated to bingbang v1.0.2.0.</li>
</ul>]]></content:encoded>
          </item>
          <item>
            <title>AWC 500 PCM5.2 OS - v3.0.7.1</title>
            <link>https://deif-staging.jcdhotel.dk/software/awc-500-pcm52-os/3-0-7-1/</link>
            <atom:link rel="related" href="https://deif-staging.jcdhotel.dk/software/24795.xml" type="application/rss+xml" />
            <guid isPermaLink="true">33e7e445-8fab-46a3-97c2-2d5a3ee92de4</guid>
            <pubDate>2025-12-16T00:00:00&#x2B;00:00</pubDate>
            <category domain="item-type">software-version</category>
            <category domain="software">AWC 500 PCM5.2 OS</category>
            <category domain="version">3.0.7.1</category>
            <category domain="release-status">current</category>
                    <content:encoded><![CDATA[<p>This release contains minor corrections and changes.</p>
<h3>Corrections</h3>
<ul>
<li>Bug causing link loss on EoE interfaces after EtherCAT rescan.</li>
<li>Fixed module list on the web interface.</li>
<li>Fixed selection of the time zone "(GMT-08:00) Pacific Time (US &amp; Canada)" in the web interface.</li>
<li>Problem with logc tail -f not showing new log lines.</li>
<li>Bug causing logc cat to fail with "too many open files" fail, and consequently also web interface syslog.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Updated to bingbang v1.0.2.0.</li>
</ul>]]></content:encoded>
          </item>

  </channel>
</rss>